I have an aluminum double pass radiator
with the finned core size of about 18.25 X 18.25 X 2.25. It is behind the
engine and leaning rearward at the top at about a 30-35* angle. The water from
the engine enters on the left lower and crosses the bottom half of the radiator
to the right side then rises and goes back across the top of the radiator and
exits the top left side and returns to the engine.
My radiator cap is at the top right corner
of the radiator at the point where the water starts its second pass through the
top half. My pressure port is just below the radiator cap. The pressure
sending unit is in a “T” with the hose which goes to the ¼” port
at the top of the rear iron connected to the other side of the “T”.
I thought that this hose could have some effect on the pressure, but I am not
certain why it would.
Any air in the system should either rise
to the top of the radiator, or if it was trapped in the block, it could come
through the hose to the radiator. All air should be found therefore? Under the
radiator cap. I have never found any air there.
I think I found out a little something
about the fuel system today. I only put a few gallons in the right tank and
have been checking for leaks and running the engine on this fuel. I wanted to
run it down to the “non-usable” level and then do the same thing
with the left tank. So I have been really low on fuel. My pressure has been
holding, but I thought that I could hear bubbles from time to time going
through the lines.
Anyway, before, I could get a good start
by setting the mixture at about 4 PM oclock and it would fire up in a couple of
blades. Today, I tried hitting the primer button a couple of times and it
would start and immediately die. I finally had to set the cold start on and
leave it on just to get the engine to run! Finally after it warmed up, it ran
with the mixture set at 12 oclock, but it was not steady. As my fuel ran out,
the pressure dropped finally to about 28 lbs and the engine started its death
rattle. I shut it off at that time.
The temperature had risen to 210* the
ambient temp was 87-88* and the air after the radiator was 168* This is with
my radiator fan running. (11” and 970 CFM) probably about 10-12 minutes
of running the engine
.
My oil temp was only 160* and the air temp
after the oil cooler was 145* , I think that this would gone higher if I ran
longer, because the oil in the pan was up to 170-180* or so. The pan holds 5
qts, 8 qts in the system.
Water pressure was up to 22-23 lbs and oil
pressure was 70 lbs.
All my temp probes are within a degree or
so of one another and with a mercury thermometer in the hangar when reading
ambient temp and the engine is cold. I think they are all correct.
I have the air/fuel ratio setup that comes
with the EM-2, but it doesn’t work till the O2 sensor gets to about 800*
or so, no help on trying to figure out starting ratio.
The timing brings up a good point. I got
the Renesis out of a wrecked car with 1800 miles on it, so the timing is set to
the factory setting for the Renesis. I have never checked it. Does anyone know
what the factory setting would be for the Renesis??
Staging is a good point, but I think that
you are correct about having enough fuel to run a low speeds and not enough to
run faster. I was running out of fuel and probably didn’t have enough to
rip it.
You really have good insights when you are
helping folks.. You are pretty right on with your advice.
Thanks,
Bill B (Must mow yard…Must mow yard..)
From: Rotary motors in aircraft
[mailto:flyrotary@lancaironline.net] On
Behalf Of Ed Anderson
Sent: Wednesday, October 03, 2007
12:53 PM
To: Rotary
motors in aircraft
Subject: [FlyRotary] Re: Problem?
[FlyRotary] Re: Coolant Water Pressure
Yes, too hot for that rpm, I agree.
Assuming you followed the good suggestions offered by
Al, Lynn and others regarding getting all the air out of the block - really
important! I almost cooked engines two times because of excess air in the
coolant system. Here is something that may quickly tell you
something about the air you may have in the system.
I can't recall what type of radiator set up you have,
but with the Two GM cores I use which are mounted vertically, you can
touch the side tank of the radiator and determine if there is air in the
system. In my case, if I do a complete drain and refill of the
system, on the first run up the core's tanks will be hot approx 2/3 of
the way up and then they are much cooler - indicating that the remaining 1/3 of
my core is filled with air. It generally takes me 3 runups
reaching 5000 rpm before I can touch the core tanks and find
them hot all the way from top to bottom. So depending on your radiator
set up that might be something you can quickly check.
If the mixture is too lean, you can get a backfire out the
intake, too rich and its generally the exhaust - where unburned fuel cooks
off. So that and black smoke would indicate to me too rich a
mixture. I presume you do not have an Air/Fuel ratio indicator - strongly
recommend you get one, that tells you right away whether you are running rich
or lean. Even a cheap one can be a tremendous help in finding out whether
too rich or too lean.
One thing you may want to check is your ignition timing.
If using Tracy's
EC2 you need to set the static timing around 35 Deg BTDC. The EC2 backs
off 10 deg from that (25Deb BTDC) as its default starting point for ignition
timing. So if you set the static timing to say 25 Deg then the EC2 would
be having the engine operate at a 25 - 10 deg = 15 Deg BTDC which is pretty
retarded timing for the rotary. OR if you set it too far advanced
then the timing might be too advanced.
So just recheck it when you get the chance.
Another possibility is your injection system might not be
staging properly. IF that were the case, the engine might work fine below
the staging point but not above it. Could possibly be a sticking
secondary injector (if too rich or lean). But, that is a bit down
the likely list. Something impeding the fuel flow might provide
sufficient fuel and low rpm but not sufficient to run at high rpm.
----- Original Message -----
Sent: Wednesday, October
03, 2007 11:23 AM
Subject: [FlyRotary] Re:
Problem? [FlyRotary] Re: Coolant Water Pressure
Ed, this is at about 2000 rpm. Like
a fast idle. I am getting all kinds of fuel cut like stoppages if I try
to run the engine faster. I haven’t seen more than about 3700 rpm,
but I just started it and have not tried to tune anything. I figure I
will have to run longer to get it tuned and the cooling is holding that back.
Speaking of that, you guys were talking a
while back about the effects you see when the engine is too lean, or too
rich. Talking about backfires, etc and what each effect represents.
I have forgotten what means what…senior days, not moments!
Do any of you remember how that
went? I am having some problems getting started and am not certain if I
am too rich or too lean. I am getting backfires out the exhaust at times
and smoke from the exhaust at that time. (black)
I ran the batteries down yesterday trying
to get started due to this. When I originally started the engine, I
flooded it. I am trying to prevent this now and am concerned that I may
not be using enough mixture.
Bill B
From: Rotary motors in aircraft [mailto:flyrotary@lancaironline.net]
On Behalf Of Ed Anderson
Sent: Wednesday, October 03, 2007
10:05 AM
To: Rotary
motors in aircraft
Subject: [FlyRotary] Problem?
[FlyRotary] Re: Coolant Water Pressure
You indicate you get overheating after 10-15 minutes run
time. I may have missed it, but is this at idle, max throttle or
what. Also what is your OAT. If at idle or low power then, yes what
you are seeing is not what it should be. On the other hand, if at WOT or
high power settings, then 10-15 minutes run time would be indication of a great
cooling capacity. I can not run my engine more than a minute or two at
WOT on a 80F day without temps getting into the 200F range. But, that is
at 5800-6000 rpm. At idle, the temps stabilize and I can idle all day
with safe temps.
My coolant system runs with no air cushion and yes, I get a
hydraulic "lock" pressure reading of as high as 25 psi immediately
upon engine start up. After a 30 - 60 seconds of running
the pressure drops down to zero and then after a few minutes running
builds back up as the coolant warms up to operating temperatures.
Plenty of suggestion have been made about what to check -
all good.
----- Original Message -----
Sent: Wednesday, October
03, 2007 9:30 AM
Subject: [FlyRotary] Re:
Coolant Water Pressure
Bill, the definitive test is the one I described below.
Really encourage you to do it as described. Resist assumptions. Convert your
ideas to measurements.
----- Original Message -----
Sent: Wednesday, October
03, 2007 6:08 AM
Subject: [FlyRotary] Re:
Coolant Water Pressure
I think that I would see air under the radiator
cap if I had a compression gas leak? I never see any air.
To check a piston engine for head gasket
leaks, you would put the cylinder at TDC and pressurize the cylinder to about
150 lbs with compressed air and check the radiator for air bubbles…How do
you check a rotary?
I will check the pressure sender against a
mechanical gage.
There is obviously a heating problem, but
I think the pressure is higher than it should be until just ready to
boil. I shut the engine off at 210*, and at 22+ lbs, the boiling point
should be well above 250*??
Thanks for the suggestions of where to
look, guys…
Bill B
From: Rotary motors in aircraft
[mailto:flyrotary@lancaironline.net] On
Behalf Of Al p Wick
Sent: Tuesday, October 02, 2007
7:49 PM
To: Rotary
motors in aircraft
Subject: [FlyRotary] Re: Coolant
Water Pressure
Your coolant reservoir should be above engine.
1) If it is, remove two cups of air from the reservoir. Then repeat
your test.
2) If you now see pressure rise above 22 psi within 5 minutes of
cold start, you clearly have compression gases leaking into cooling system or
bad gage.
3) Air in the block is 10 times more significant than any other cooling
factor. Make darn sure you don't have any. It causes local boiling, high temps,
strange behavior.
Operating with two cups of air under cap is an important safety and
diagnosis advantage. Everyone should do it. With that two cups, you only see 22
psi if you have a genuine problem. You only see 0 psi if you have genuine
problem. The pressure is then a very fast and reliable indicator of system
integrity. So two cups of air has no negative effect on system efficiency, just
a substantial improvement in safety. Only time it could be a negative would be
if your reservoir was way too small, way too low, or flowed way too much
coolant.
Since you describe high temps AND pressure, I suspect you have
temperature problem.
I deliberately overheated my engine many times so that I was intimate
with pressure and temperature patterns. Then tested various concepts.
Don't recommend you do the same.
I just recently got my Renesis started again after finishing
my cowl. I seem to be getting very high coolant pressures. I can
only run the engine about 10-15 minutes before hitting the redline at
210*. My water pressure is at 27 Lbs at that time. I only have a 22
Lb radiator cap, so I assume that I am blowing into the recovery tank, but I
have not confirmed that. My oil temp has never exceeded about 165*.
It might have gone higher if I could have run longer???
This whole water pressure thing has me a little
baffled. Since this is a closed system and the only way pressure can
build is due to the expansion of the coolant after heating???, I am confused by
some comments that have been made from time to time. I remember something
that Tracy said
about his pressure would build for a time, then go to zero. It seems to
me that the pressure should correlate to the temp pretty closely since it is a
closed system??
Can someone enlighten me a little on the science of this
pressure? It seems to me that there could be some pressure build up on
the positive side of the pump, but it would go negative on the suction side, so
the net effect of the pump should be close to zero??
Also, my Renesis had only 1800 miles on it when I bought it,
so I did not have to tear it down. As a result, I am somewhat in the dark
as to how the water flows through the system. Could someone help me with
that? I had to remove the thermostat tower for height clearance , so I
made an adapter plate that takes water from the top outlet of the pump and
sends it to the radiator (double pass), then from the radiator, it returns to
the lower inlet of the pump.
Thanks,
Bill B