X-Virus-Scanned: clean according to Sophos on Logan.com X-SpamCatcher-Score: 1 [X] Return-Path: Received: from bay0-omc1-s31.bay0.hotmail.com ([65.54.246.103] verified) by logan.com (CommuniGate Pro SMTP 5.1.5) with ESMTP id 1781786 for flyrotary@lancaironline.net; Sun, 21 Jan 2007 20:04:40 -0500 Received-SPF: pass receiver=logan.com; client-ip=65.54.246.103; envelope-from=lors01@msn.com Received: from hotmail.com ([65.54.250.83]) by bay0-omc1-s31.bay0.hotmail.com with Microsoft SMTPSVC(6.0.3790.2668); Sun, 21 Jan 2007 17:03:53 -0800 Received: from mail pickup service by hotmail.com with Microsoft SMTPSVC; Sun, 21 Jan 2007 17:03:53 -0800 Message-ID: Received: from 4.171.150.250 by BAY115-DAV11.phx.gbl with DAV; Mon, 22 Jan 2007 01:03:51 +0000 X-Originating-IP: [4.171.150.250] X-Originating-Email: [lors01@msn.com] X-Sender: lors01@msn.com From: "Tracy Crook" To: "Rotary motors in aircraft" References: Subject: Re: [FlyRotary] EC2 Injector Wiring Date: Sun, 21 Jan 2007 20:03:48 -0500 MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0184_01C73D97.4375AD10" X-Priority: 3 X-MSMail-Priority: Normal X-Mailer: MSN 9 X-MIMEOLE: Produced By MSN MimeOLE V9.50.0034.2000 Seal-Send-Time: Sun, 21 Jan 2007 20:03:48 -0500 X-OriginalArrivalTime: 22 Jan 2007 01:03:53.0196 (UTC) FILETIME=[2F200AC0:01C73DC1] Return-Path: lors01@msn.com This is a multi-part message in MIME format. ------=_NextPart_000_0184_01C73D97.4375AD10 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable Most of those cautionary notes are based on occasional feedback from = other users but it only makes sense to do it if the space is available. = I have never seen any interaction in my own installations even with = several feet of side by side wiring of all the harness wires (except = ignition coil power & ground wires). I can't imagine that the very = short run you describe would cause a problem. Tracy ----- Original Message -----=20 From: Scott=20 To: Rotary motors in aircraft=20 Sent: Saturday, January 20, 2007 9:25 AM Subject: [FlyRotary] EC2 Injector Wiring The EC2 doc is pretty emphatic on the keeping the injector wiring separate. On the instrument side of the firewall this bundle is kept 4-6" away from the other EC2 wiring and EM2 wiring. Similarly, on the engine side of the firewall, the injector wiring bundle goes immediately left and the other ec2 and em2 wiring bundles go immediately right. However, where they go through the firewall the bundles do come close together. The nearest the injector bundle gets is approximately 1" to the other EC2 bundle. Should I expect issues with the proximity? If so, is it possible to mitigate these issues? Thx... -Scott=20 =20 = _________________________________________________________________________= ___________ Sucker-punch spam with award-winning protection.=20 Try the free Yahoo! Mail Beta. = http://advision.webevents.yahoo.com/mailbeta/features_spam.html=20 ------=_NextPart_000_0184_01C73D97.4375AD10 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
Most of those cautionary notes are based on occasional feedback = from other=20 users but it only makes sense to do it if the space is = available.  I=20 have never seen any interaction in my own installations even with = several feet=20 of side by side wiring of all the harness wires (except ignition coil = power=20 & ground wires).   I can't imagine that the very short run = you=20 describe would cause a problem.
 
Tracy
----- Original Message -----
From: Scott
To: Rotary motors in = aircraft
Sent: Saturday, January 20, = 2007 9:25=20 AM
Subject: [FlyRotary] EC2 = Injector=20 Wiring

The EC2 doc is pretty emphatic on the keeping = the
injector=20 wiring separate.  On the instrument side of
the firewall this = bundle=20 is kept 4-6" away from the
other EC2 wiring and EM2 wiring. =20 Similarly, on the
engine side of the firewall, the injector=20 wiring
bundle goes immediately left and the other ec2 and = em2
wiring=20 bundles go immediately right.  However, where
they go through = the=20 firewall the bundles do come close
together.  The nearest the = injector=20 bundle gets is
approximately 1" to the other EC2 = bundle.

Should I=20 expect issues with the proximity?  If so, is
it possible to = mitigate=20 these issues?

Thx...
-Scott=20 =


 