Mailing List flyrotary@lancaironline.net Message #240
From: Michael Robert <pmrobert@telocity.com>
Sender: Marvin Kaye <marv@lancaironline.net>
Subject: Re: [FlyRotary] Re: EWP water pump
Date: Mon, 14 Oct 2002 00:06:30 -0400
To: <flyrotary>
Marvin Kaye wrote:

Posted for Jim Sower <canarder@starband.net>:

I thought that in a closed system there was no head pressure.  If the system is
pressurized, there is system pressure, but still no head pressure.  The closed loop
cancels everything out.
Just wonderin' .... Jim S.


        Yes, I do think it would account for errors in the test. Head pressures on
pumps are a big factor in sizing pumps & motors in industry.


 Homepage:  http://members.rogers.com/flyrotary/



There would be no "head pressure" - there will be friction loss - different animal, same effect, except that friction loss will scale with flow.

   -Mike

--