Return-Path: Received: from [24.25.9.103] (HELO ms-smtp-04-eri0.southeast.rr.com) by logan.com (CommuniGate Pro SMTP 4.3c2) with ESMTP id 765500 for flyrotary@lancaironline.net; Tue, 01 Mar 2005 17:35:37 -0500 Received-SPF: pass receiver=logan.com; client-ip=24.25.9.103; envelope-from=eanderson@carolina.rr.com Received: from edward2 (cpe-024-074-185-127.carolina.rr.com [24.74.185.127]) by ms-smtp-04-eri0.southeast.rr.com (8.12.10/8.12.7) with SMTP id j21MYmCi010913 for ; Tue, 1 Mar 2005 17:34:49 -0500 (EST) Message-ID: <001701c51eae$e902ba20$2402a8c0@edward2> From: "Ed Anderson" To: "Rotary motors in aircraft" References: Subject: Re: [FlyRotary] Re: Filterr or not to Filter: [FlyRotary] Re: FW: Cooling system update Date: Tue, 1 Mar 2005 17:35:02 -0500 MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0014_01C51E84.FFFCEF90" X-Priority: 3 X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook Express 6.00.2800.1106 X-MIMEOLE: Produced By Microsoft MimeOLE V6.00.2800.1106 X-Virus-Scanned: Symantec AntiVirus Scan Engine This is a multi-part message in MIME format. ------=_NextPart_000_0014_01C51E84.FFFCEF90 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable Mark, I have a nice one written down, but guess it wouldn't take long to = do that. Perhaps we could start one and folks could add to it. They = will need to tailor it for their own installation in any case. I'll write down what I inspect (focusing mainly on the FWF area) and = post it. For instance I inspect each inch of fuel line FWF - last = inspection I found a stainless steel braided line which returns fuel = from pressure regulator to sump tank leaking (oozing) through the braid = about 2" above the sump fitting- not under any stress/heat/pressure in = that area, so a bit of a surprise - about the last place I would have = expected the line to leak. )=20 Ed The major FWF categories I focus on are: Fuel System Ignition System Lubrication System Coolant System Engine a. Induction b. Exhaust Gearbox Electrical System EC2 Prop/Spinner Motor Mount For example on the Fuel system here is what I check for. Fuel System: 1. Check all FWF Fuel connections/lines for evidence of = leaks/chaffing/damage (examine connections closely)=20 2. Drain Sump tank, remove quick drain, inspect "O" ring - replace = drain 3. Disconnect and inspect coarse fuel filter screens - replace. 4. Turn on Boost(Low pressure pump), time required to re-fill sump < = =3D 3 seconds 5. Remove and Replace EFI high pressure fuel filters (Check Saginaw "O" = rings - replace if needed) 6. Check Both EFI pumps for pressure a. Disconnect and block fuel return to Pressure regulator (I = simply screw on an An-6 cap to the disconnected fuel line fitting) b. Check that Main pump puts out at least 60 psi (Pressure sensor = after pump and filter but before fuel rail) c. Check that back-up pump puts out at least 80 psi d. Reconnect Pressure Regulator 7. Reconnect components and test for pressure regulation (40 psi min) 8. Check around fuel injectors for any sign of leakage (generally a = sign of bad "O" rings) 9. Re-inspect for any new leaks (Important - I have found that at 40 = psi fuel can find its way out if there is any path open) ----- Original Message -----=20 From: Mark R Steitle=20 To: Rotary motors in aircraft=20 Sent: Tuesday, March 01, 2005 1:56 PM Subject: [FlyRotary] Re: Filterr or not to Filter: [FlyRotary] Re: FW: = Cooling system update Ed, Do you have an annual "rotary-engine" checklist that you would be = willing to share with the group. If not, then you've got my email = address. ;-) =20 Mark =20 -------------------------------------------------------------------------= ----- From: Rotary motors in aircraft [mailto:flyrotary@lancaironline.net] = On Behalf Of Ed Anderson Sent: Tuesday, March 01, 2005 12:53 PM To: Rotary motors in aircraft Subject: [FlyRotary] Re: Filterr or not to Filter: [FlyRotary] Re: FW: = Cooling system update =20 Well, Mark, that was easier than taking the Ross drive off each = annual for inspection. Nothing to show for it either - until after = approx 160 hrs of flying when I noticed the Sun gear and one of the = planetary gear teeth were galling. Of course, then I had a good excuse = to buy Tracy's PSRU. I also do compression checks at each annual = although not having a "real" rotary compression checker all it really = tells me is that my seals are OK and compression is nominal for each = rotor (not a big deviation in pressure between the faces). =20 I may be a bit anal retentive about annuals, but in my opinion it is a = once a year thing that can catch things (like the Ross, or radiator = gunk) before they become catastrophic. Just my personal opinion of = course. =20 Ed A =20 =20 ----- Original Message -----=20 From: Mark R Steitle=20 To: Rotary motors in aircraft=20 Sent: Tuesday, March 01, 2005 12:19 PM Subject: [FlyRotary] Re: Filterr or not to Filter: [FlyRotary] Re: = FW: Cooling system update =20 =20 WOW Ed, I'm impressed. I wonder how many can honestly say they go = to this level of detail on their annuals? =20 =20 Mark =20 =20 I stick a small "Inspection mirror" up through the AN-16 fitting = with a small light shinning on the mirror. (I think next time I will = wire a small LED to the head of the mirror - would make it much easier) = I then run the mirror up and down the side tank and rotate it at = intervals looking mainly at the condition of the small 1/8-1/4" dia = cross tank tubes. I look for blockage or any indication of scale/gunk. = Thus far I have found none. =20 =20 Ed A =20 ------=_NextPart_000_0014_01C51E84.FFFCEF90 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
Mark, I have a nice one written down, = but guess it=20 wouldn't take long to do that.  Perhaps we could start one and = folks could=20 add to it. They will need to tailor it for their own installation in any = case.
 
 I'll write down what I inspect = (focusing=20 mainly on the FWF area) and post it. For=20 instance I inspect each inch of fuel line FWF - last inspection I=20 found a stainless steel = braided line=20 which returns fuel from pressure regulator to sump tank leaking (oozing) = through=20 the braid about 2" above the sump fitting- not under any = stress/heat/pressure in=20 that area, so a bit of a surprise - about the last place I would have = expected=20 the line to leak.  )
 
Ed
 
The major FWF categories I focus on=20 are:
 
Fuel System
Ignition System
Lubrication System
Coolant System
Engine
   a.  Induction
   b.  Exhaust
Gearbox
Electrical System
EC2
Prop/Spinner
Motor Mount
 
For example on the Fuel system here is = what I check=20 for.
 
Fuel = System:
1.  Check all FWF Fuel = connections/lines for=20 evidence of leaks/chaffing/damage (examine connections=20 closely) 
2.  Drain Sump tank, remove quick = drain,=20 inspect "O" ring - replace drain
3.  Disconnect and inspect coarse = fuel filter=20 screens - replace.
4.  Turn on Boost(Low pressure = pump), time=20 required to re-fill sump < =3D 3 seconds
5.  Remove and Replace EFI high = pressure fuel=20 filters (Check Saginaw "O" rings - replace if = needed)
6.  Check Both EFI pumps for=20 pressure
    a.  Disconnect = and block=20 fuel return to Pressure regulator (I  simply screw on an An-6 = cap to=20 the disconnected fuel line fitting)
    b.  Check that = Main pump=20 puts out at least 60 psi (Pressure sensor after pump and filter but = before fuel=20 rail)
    c.  Check that = back-up pump=20 puts out at least 80 psi
    d.  Reconnect = Pressure=20 Regulator
7.  Reconnect components and test = for pressure=20 regulation (40 psi min)
8.  Check around fuel injectors = for any sign=20 of leakage (generally a sign of bad "O" rings)
9.  Re-inspect for any new leaks = (Important -=20 I have found that at 40 psi fuel can find its way out if there is any = path=20 open)
 
 
 
 
 
 
 
 
 
 
----- Original Message -----
From:=20 Mark R Steitle =
Sent: Tuesday, March 01, 2005 = 1:56=20 PM
Subject: [FlyRotary] Re: = Filterr or not=20 to Filter: [FlyRotary] Re: FW: Cooling system update

Ed,

Do you have = an annual=20 =93rotary-engine=94 checklist that you would be willing to share with = the=20 group.  If not, then you=92ve got my email address. =20 ;-)

 

Mark

 


From: = Rotary motors=20 in aircraft [mailto:flyrotary@lancaironline.net] On Behalf Of Ed = Anderson
Sent: Tuesday, March 01, 2005 = 12:53=20 PM
To: Rotary = motors in=20 aircraft
Subject: = [FlyRotary]=20 Re: Filterr or not to Filter: [FlyRotary] Re: FW: Cooling system=20 update

 

Well, = Mark,=20  that was easier than taking the Ross drive off each annual for=20 inspection.  Nothing to show for it either - until after approx = 160 hrs=20 of flying when I noticed the Sun gear and one of the planetary gear = teeth were=20 galling.  Of course, then I had a good excuse to buy Tracy's = PSRU.  I=20 also do compression checks at each annual although not having a "real" = rotary=20 compression checker all it really tells me is that my seals are OK and = compression is nominal for each rotor (not a big deviation in pressure = between=20 the faces).

 

I may = be a bit=20 anal retentive about annuals, but in my opinion it is a once a year = thing that=20 can catch things (like the Ross, or radiator gunk) before they become=20 catastrophic. Just my personal opinion of = course.

 

Ed=20 A

 

 

-----=20 Original Message -----

From: Mark R Steitle=20

Sent: = Tuesday,=20 March 01, 2005 12:19 PM

Subject: = [FlyRotary]=20 Re: Filterr or not to Filter: [FlyRotary] Re: FW: Cooling system=20 update

 

 

WOW  = Ed, I=92m=20 impressed.  I wonder how many can honestly say they go to this = level of=20 detail on their annuals? 

 

Mark

 

 

I = stick a=20 small "Inspection mirror" up  through the AN-16 fitting = with a=20 small light shinning on the mirror. (I think next time I will = wire a=20 small LED to the head of the mirror - would make it much = easier) =20  I then run the mirror up and down the side tank and rotate it = at=20 intervals looking mainly at the condition of the small 1/8-1/4" dia = cross=20 tank tubes.  I look for blockage or any indication of = scale/gunk. =20 Thus far I have found none. 

 

Ed=20 A

 