In a message dated 1/22/2005 8:46:01 PM Pacific Standard Time, eanderson@carolina.rr.com writes:
I think I may have found my problem with the pressure regulator. Seen below (the Boost Adjustable one is the one I use). In the description they mention are adjustable from 36-45 psi with a flow rate of 9.2-10.5 gal/hr. I presume that means the return rate flow or if they mean the engine fuel used flow rate then clearly it is under-capacity to handle our rotary fuel flow.
Ed, I hadn't read this post yet when I posted my long-winded reply. (previous post)
Looks like you got the idea on your own. The pump IS higher output than you need.
The regulator itself may be the return restriction I mentioned in the previous post!
Bill Jepson
|
|