Al Gietzen wrote:
Subject: [FlyRotary] EGT sensors
Time to change the EWP subject:)
At the rotary roundup Tracy mentioned that if you have two EGT sensors, you
can tune each rotor separately. Does anybody have two EGT sensors, how they
are mounted and where do you get them?
Bulent
-----
I have three (20B) inconel clad K-type, clamp-in. One in each header a
couple inches from the port. Got mine from Grand Rapids Technologies, but
you may alos be able to get them from Omega. They are built into a hose
clamp so you drill the hole, tighten the clamp, seal up tight.
Al
Don't you mean J-type? I believe K is lower temperature.
Finn
|
|