Return-Path: <13brv3@bellsouth.net> Received: from imf25aec.mail.bellsouth.net ([205.152.59.73] verified) by logan.com (CommuniGate Pro SMTP 4.2.4) with ESMTP id 451880 for flyrotary@lancaironline.net; Mon, 04 Oct 2004 08:48:02 -0400 Received-SPF: pass receiver=logan.com; client-ip=205.152.59.73; envelope-from=13brv3@bellsouth.net Received: from rd ([65.6.194.9]) by imf25aec.mail.bellsouth.net (InterMail vM.5.01.06.11 201-253-122-130-111-20040605) with ESMTP id <20041004124731.PIXW1789.imf25aec.mail.bellsouth.net@rd> for ; Mon, 4 Oct 2004 08:47:31 -0400 From: "Russell Duffy" <13brv3@bellsouth.net> To: "'Rotary motors in aircraft'" Subject: RE: [FlyRotary] Re: MAP pulses (20B) Date: Mon, 4 Oct 2004 07:47:54 -0500 Message-ID: <007601c4aa10$5e335e80$6101a8c0@rd> MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0077_01C4A9E6.755D5680" X-Priority: 3 (Normal) X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook, Build 10.0.6626 Importance: Normal X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.2180 In-Reply-To: This is a multi-part message in MIME format. ------=_NextPart_000_0077_01C4A9E6.755D5680 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: quoted-printable I set the EC2 to mode 7, ran the engine up to 15.5" MAP based on the = gauge, and pressed the set button; to try to be sure the stage point was = properly set. Didn't seem to make any difference. It still bothers me that you see a change in the engine when turning off = the secondaries below the staging point. Since the staging default is 15", setting it at 15.5" is still very close to the same thing. Try setting = the staging point up to 18" or so, just to make sure it's so far away from = the MAP you're running in your tests that it can't possibly intermittently stage. I keep mine up there all the time, and I think Tracy might be = doing that as well. With mismatched injectors, you'll find that the higher = you set the staging point, the better the transition will be, since the = engine is more tolerant of mixture changes at higher power settings. =20 =20 I'm not surprised that the secondaries (MSD 525) are running smoother = than the primaries (Mazda 550) at low power. One of the problems with larger injectors is that you can't cut the pulse width down enough to limit the fuel for idle settings. Also, when running minimal pulse widths, the reaction time of the injector becomes a factor. If there's any = variation in the opening and closing time of the injector (partly sticking, worn out, etc), this will cause big problems at idle, and lesser problems as you increase the power setting. =20 Checked the staging relay and secondary power circuit is "on" when everything is off (relay not energized). With engine off, EC2 on, relay = is energized and secondary power is off (not sure this is normal). = However; with engine running and MAP below stage point, relay is not energized, = and secondary power is "on" (not normal). Relay coil connects to +12 and to = pin 35, which I understand closes to ground when MAP is below staging point. What "staging relay" are you referring to?=20 Well, now that the plane is flying again, I guess I have to clean up all = the limbs and downed trees in the yard. Rusty (priorities in order) ------=_NextPart_000_0077_01C4A9E6.755D5680 Content-Type: text/html; charset="us-ascii" Content-Transfer-Encoding: quoted-printable Message

I set the EC2 to mode 7, ran the engine up to = 15.5” MAP based on=20 the gauge, and pressed the set button; to try to be sure the stage point = was=20 properly set.  Didn’t seem to make any difference.

It still = bothers me that=20 you see a change in the engine when turning off the secondaries below = the=20 staging point.  Since the staging default is 15", setting it = at 15.5"=20 is still very close to the same thing.  Try setting the staging = point up to=20 18" or so, just to make sure it's so far away from the MAP you're = running in=20 your tests that it can't possibly intermittently stage.  I keep = mine up=20 there all the time, and I think Tracy might be doing that as well.  = With=20 mismatched injectors, you'll find that the higher you set the staging = point, the=20 better the transition will be, since the engine is more tolerant of = mixture=20 changes at higher power settings.  
 
I'm not = surprised that=20 the secondaries (MSD 525) are running smoother than the primaries = (Mazda=20 550) at low power.  One of the problems with larger injectors is = that you=20 can't cut the pulse width down enough to limit the fuel for idle=20 settings.  Also, when running minimal pulse widths, the = reaction time=20 of the injector becomes a factor.  If there's any variation in the = opening=20 and closing time of the injector (partly sticking, worn out, etc), this = will=20 cause big problems at idle, and lesser problems as you increase the = power=20 setting.     

Checked the staging relay and secondary power circuit is = “on” when everything=20 is off (relay not energized).  With engine off, EC2 on, relay is = energized=20 and secondary power is off (not sure this is normal).  However; = with engine=20 running and MAP below stage point, relay is not energized, and secondary = power=20 is “on” (not normal).  Relay coil connects to +12 and = to pin 35, which I=20 understand closes to ground when MAP is below staging point.

What "staging = relay" are you=20 referring to?

Well, now that the plane is flying = again, I=20 guess I have to clean up all the limbs and downed trees in the = yard.

Rusty (priorities in=20 order)