Message
I recently installed a set of VDO sensors in these inputs to measure oil
pan & coolant in. Neither are working. I've input the scale factor &
offset from the other liquid temp sensors, but these both read 281F regardless
of temp. I've switched sensor inputs to confirm sensor operation. I've measured
the circuit resistance and found both aux. liquid circuit inputs to be ~450
ohms, while the main liquid temp input circuits are <100 ohms. I've been
meaning to call Tracy about this, but I've just been too damn
busy.
S. Todd
Bartrim
Stand by.
I may know this one. My previously mentioned failing memory (we think
the MRI magnets do this) seems to recall something special that had to be done
to some of the inputs. If I'm correct, the aux temps were the
ones that needed a pull-up resistor added. I'm heading to the hanger
in a few minutes, so I'll look through my info at the hanger, and try to find
the details. I sure hope I didn't throw this away when I got the new
manual.
Cheers,
Rusty (at least
mine work)
|