Return-Path: Received: from corpprd-pxy2.canfor.ca ([198.162.160.3] verified) by logan.com (CommuniGate Pro SMTP 4.2) with ESMTP id 378180 for flyrotary@lancaironline.net; Wed, 25 Aug 2004 16:11:03 -0400 Received-SPF: none receiver=logan.com; client-ip=198.162.160.3; envelope-from=Steve.Bartrim@canfor.com Received: from canformail1.canfor.ca (canformail1.canfor.ca [199.60.193.29]) by corpprd-pxy2.canfor.ca (Build 103 8.9.3p2/NT-8.9.3) with ESMTP id NAA03613 for ; Wed, 25 Aug 2004 13:10:33 -0700 X-MimeOLE: Produced By Microsoft Exchange V6.5.7226.0 Content-class: urn:content-classes:message Subject: RE: [FlyRotary] Re: EM2 users Date: Wed, 25 Aug 2004 13:10:29 -0700 MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----_=_NextPart_001_01C48ADF.911BE100" Message-ID: <1F17B59A61D4194095359264D24D22A2708CC6@mailman.canfor.ca> X-MS-Has-Attach: X-MS-TNEF-Correlator: Thread-Topic: [FlyRotary] Re: EM2 users Thread-Index: AcSK09iScHjYroCfSSOwVeBz4tvBbAABZOcg From: "Bartrim, Todd" To: "Rotary motors in aircraft" This is a multi-part message in MIME format. ------_=_NextPart_001_01C48ADF.911BE100 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable > Anybody using > '> Aux Liquid temps> '> 2&3? Mine aren> '> t = working right. >=20 > I'm using two of the aux liquid temps for oil pan, and water into the = engine, but I can't recall the exact designations of the channels. In = fairness to my failing memory, they do tend to change names from one = page to the next, much like the buttons do :-) I know these were = working fine in the previous software version, but just made a note to = confirm they're working now. =20 >=20 I recently installed a set of VDO sensors in these inputs to measure = oil pan & coolant in. Neither are working. I've input the scale factor & = offset from the other liquid temp sensors, but these both read 281F = regardless of temp. I've switched sensor inputs to confirm sensor = operation. I've measured the circuit resistance and found both aux. = liquid circuit inputs to be ~450 ohms, while the main liquid temp input = circuits are <100 ohms. I've been meaning to call Tracy about this, but = I've just been too damn busy. S. Todd Bartrim Turbo 13B RX-9endurance C-FSTB http://www3.telus.net/haywire/RV-9/C-FSTB.htm "Imagination is more important than knowledge" -Albert Einstein ------_=_NextPart_001_01C48ADF.911BE100 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable RE: [FlyRotary] Re: EM2 users

    Anybody using = ‘Aux Liquid temps’ 2&3?   Mine aren’t = working right.

I'm using = two of the aux liquid temps for oil pan, and water into the engine, but = I can't recall the exact designations of the channels.  In fairness = to my failing memory, they do tend to change names from one page to the = next, much like the buttons do :-)   I know these were working = fine in the previous software version, but just made a note to confirm = they're working now. 

        I recently installed a set of VDO sensors in = these inputs to measure oil pan & coolant in. Neither are working. = I've input the scale factor & offset from the other liquid temp = sensors, but these both read 281F regardless of temp. I've switched = sensor inputs to confirm sensor operation. I've measured the circuit = resistance and found both aux. liquid circuit inputs to be ~450 ohms, = while the main liquid temp input circuits are <100 ohms. I've been = meaning to call Tracy about this, but I've just been too damn = busy.

S. Todd = Bartrim
Turbo = 13B
RX-9endurance
C-FSTB
http://www3.telus.= net/haywire/RV-9/C-FSTB.htm

        "Imagination is more important than = knowledge"
        =         =         =         =         -Albert Einstein