Mailing List flyrotary@lancaironline.net Message #10458
From: Bob White <bob@bob-white.com>
Subject: Re: [FlyRotary] Re: Answer to when is 2 gallons enough?Re: DeltaT Coolant was : [FlyRotary] Re: coolant temps
Date: Sun, 15 Aug 2004 21:57:02 -0600
To: Rotary motors in aircraft <flyrotary@lancaironline.net>
Ed,

It's a lot more efficient to publish the mistake.  A lot more people
will figure out you made a mistake than will figure out the problem in
the first place.  It saves you time, and it gets the rest of us
thinking.  :)

Bob White


On Sun, 15 Aug 2004 23:22:42 -0400
"Ed Anderson" <eanderson@carolina.rr.com> wrote:

> Dennis, I highly recommend an article on Liquid cooling that was
> published in this year's  January issue of Sport Aviation. Dr. Neal
> does an excellent job of explaining it and I have exchanged e mails
> with him on a few points.  He makes reference to a spreadsheet he
> created that will provide the coordinates for the StreamLine Ducts
> published by K&W.  This duct if done perfect produces an 84% pressure
> recovery - about the best around.  The trouble is like all ducts, it
> wants a foot or two of inlet.  However, I concluded (and Dr Neal
> agreed) that if you truncate the duct from the inlet end you preserve
> much of the goodness.  I estimated that my 6" duct length reduce
> pressure recovery by approx 20% BUT that still gave me much better
> cooling than a conventional duct would.
>
> Using the Streamline (truncated in my case) duct I was able to reduce
> my radiator intake area from a total of 48 sq inches to 33 sq inches
> and I do not believe that is the limit.  The next time I fly I'll find
> out as I have now reduced my intake area (for both GM cores) to a
> total of 28 sq inches which is slightly over 1/2 of what I have flown
> most of my hours with.  We will see within a month if all goes well.
>
> I'll keep doing the math until someone who knows (easy to find) more
> AND wants (harder to find) to hang it out.  Thanks for the comments
> and for pointing out the error.  I think what happened was I was
> thinking of the cp of water 1.0 and of air 0.25 and subconsciously
> noted the  0.75 difference and therefore that became my 1.75 product
> instead of the 4 it should have been..  I should really proof it a bit
> better, but I don't think I would have caught it without you pointing
> it out.
>
> If you REALLY want to dig into cooling try Aerodynamics of Propulsion
> by Kuchman and Weber (K&W) Aerodynamics of propulsion
>       . By: Dietrich Küchemann;  Johanna Weber
>       . Publisher: New York, McGraw-Hill, 1953.  
> This is the one I would recommend.  Unfortunately its very difficult
> to find a copy - I had to get a photo copy of one.
>
> ED
>
> Ed Anderson
> RV-6A N494BW Rotary Powered
> Matthews, NC
>   ----- Original Message -----
>   From: Dennis Haverlah
>   To: Rotary motors in aircraft
>   Sent: Sunday, August 15, 2004 10:35 PM
>   Subject: [FlyRotary] Re: Answer to when is 2 gallons enough?Re:
>   DeltaT Coolant was : [FlyRotary] Re: coolant temps
>
>
>   Ed,
>
>   Please- Please - Don't quit doing the math!!!  I am an engineer but
>   its been many years - so I really appreciate your working the
>   problems!!.  I print and save all of them.  I will be doing my
>   engine this winter and am itching to get going on it.  Right now I'm
>   half way through the wing construction.  This last math "problem"
>   had lots of good info.  I hope to expand on it to figure out cooling
>   air inlet requirements for high power climb configurations.  Also, I
>   want to look at water velocities in the hoses.  I am not sure 3/4
>   inch hose is big enough for cooling a Renesis engine at full
>   throttle.  Any comments??
>
>   Also - could you give me a good reference for inlet duct design?
>
>   Thanks in advance -
>
>   Dennis H.
>
>   Ed Anderson wrote:
>
>
>     Dennis, you are absolutely correct about my error.  In fact, you
>     pointing it out had me looking for any other errors and I am
>     embarrassed to say I found another one - but not one of a math
>     nature - it turns out both errors sort of offset each other so the
>     answer 47 mph for air velocity I got with the errors is not much
>     different than the 42 mph after doing it correctly {:>)
>
>     Thanks for pointing out my error and getting me to examine the
>     work again.
>
>     I think Rusty is right - spending too much time on  math.  You
>     will beat Rusty, I won't be able to get started until next week
>     end and by that time you 'll be finished {:<{,
>
>     Oh, the other error?
>
>     When I did my calculations for the air with my head up and locked,
>      I used the same temperature increase for the air that Tracy saw  
>      decrease in his coolant.  Well, of course  DUH!. the temperature
>      of the air will increase considerably more than that for the same
>      BTU absorbed.  In fact for the GM cores the typical Delta T
>      measured and reported  for the increase in air temps range from
>      20-30F.  In fact if you look at the static situation it only
>      takes 0.25 BTU to raise the temperature of a lbm of air 1 degree
>      F.  So you could expect the temperature of a lbm of air to be 4
>      times higher than that of water in the static situation (for the
>      same BTU).
>
>      Unfortunately its not quite that simple with flowing air.
>      Although if we continued to slow the air flow through the core
>      the temperature of the air would continue to increase - but like
>      the old boys and the radiator you would reach a point where the
>      air temps would be high due to the slowing flow - but the mass
>      flow rate would decrease to the point that less and less Heat was
>      being removed.  So again a balance is needed.
>
>     So round 2,  taking the 240 lbm of coolant that conveyed 2400 BTU
>     with a temp drop of 10F.  We find that for a more realistic
>     increase in air temps of say 25F.  we have air mass flow  W =
>     2400/(25*.25) (note I am using  the Cp 0.25 for air early in the
>     problem) = 384 lbm/minute of air to remove the 2400 BTU.
>      
>     This requires 384/0.076 = 5052 CFM of air at sea level or 5052/60
>     = 84 cubic feet/sec.  Taking our 1.32 sq ft of GM core surface we
>     find the air velocity required is 84/ 1.32 = 63 ft/sec or 42 mph
>     for our evaporator cores.   The approach with the error gave 47
>     MPH which seemed reasonable to me so I didn't even consider any
>     errors.
>
>       Gotta be more careful.  Gotta stop this math, Gotta get started
>       putting my aircraft back together, gotta go to bed
>     .
>
>     Again, thanks, Dennis
>
>     Ed.
>
>
>
>
>     So
>     Ed Anderson
>     RV-6A N494BW Rotary Powered
>     Matthews, NC
>       ----- Original Message -----
>       From: Dennis Haverlah
>       To: Rotary motors in aircraft
>       Sent: Friday, August 13, 2004 11:37 PM
>       Subject: [FlyRotary] Re: Answer to when is 2 gallons enough?Re:
>       DeltaT Coolant was : [FlyRotary] Re: coolant temps
>
>
>       Ed:
>
>       Not to pick too much but I believe there is a problem with the
>       math for the air cooling calculation.  Water has a specific heat
>       of 1 BTU/lb-deg.F. and air is 0.25 BTU/lb-deg.F. or to say it
>       another way air has 1/4 the heat capacity of the same mass of
>       water.  Hence you need 4 times the mass of water to get the same
>       heat content capacity in air. In you calculation for air, you
>       multiplied the water mass by 1.75 to get the equivilant air mass
>       required..  Shouldn't it be multiplied by 4.  
>
>       Dennis H.
>
>       Ed Anderson wrote:
>
>         I'm sorry, Mark, I did not show that step.  You are correct
>         the weight (mass) of water(or any other cooling medium) is an
>         important factor as is its specific heat.
>
>          In the example you used  - where we have a static 2 gallons
>          capacity of water, It would actually only take 8*2 = 16 lbms
>          *10 = 160 BTU to raise the temp of the water 1 degree F.  The
>          difference is in one case we are talking about raising the
>          temperature of a fixed static amount of water which can not
>          readily get rid of the heat, in the other (our radiator
>          engine case) we are talking about how much heat the coolant
>          can transfer from engine to radiator. Here the flow rate is
>          the key factor.  
>
>         But lets take your typical 2 gallon cooling system capacity
>         and see what we can determine.
>
>         If we take our 2 gallons and start moving it from engine to
>         radiator and back we find that each times the 2 gallons
>         circulates it transfers 160 BTU (in our specific example!!).
>         So at our flow rate of 30 gpm we find it will move that 160
>         BTU 15 times/minute (at 30 gallons/minute the 2 gallons would
>         be transferred 15 times).  So taking our 160 BTU that it took
>         to raise the temp of our 2 gallons of static water 10F that we
>         now have being moved from engine to radiator 15 times a minute
>         = 160*15 = 2400 BTU/Min. Amazing isn't it?   So no magic, just
>         math {:>).  So that is how our 2 gallons of water can transfer
>         2400 BTU/min from engine to radiator.  It also shows why the
>         old wives tale about "slow water" cooling better is just that
>         (another story about how that got started)
>
>
>         In the  equation Q = W*deltaT*cp that specifies how much heat
>         is transferred ,we are not talking about capacity such as 2
>         gallons capacity of a cooling system but instead are talking
>         about mass flow.  As long as we reach that flow rate  1 gallon
>         at 30 gpm or 1/ gallon at 60 gpm or 1/4 gallon at 120 gpm all
>         will remove the same amount of heat.  However if you keep
>         increasing the flow rate and reducing the volume you can run
>         into other problems - like simply not enough water to keep
>         your coolant galleys filled {:>), so there are limits.
>
>         Our  2 gallon capacity is, of course, simply recirculated at
>         the rate of 30 gpm through our engine (picking up heat- approx
>         2400 BTU/min in this specific example) and then through our
>         radiator (giving up heat of 2400 BTU/Min  to the air flow
>         through the radiators) assuming everything works as planned.
>         IF  the coolant does not give up as much heat in the radiators
>         (to the air stream) as it picks up in the engine then you will
>         eventually (actually quite quickly) over heat your engine.
>
>         The 240 lb figure I used in the previous example comes from
>         using 8 lb/gal (a common approximation, but not precise as you
>         point out) to calculate the mass flow.
>
>         The mass flow = mass of the medium (8 lbs/gallon for water) *
>         Flow rate(30 gpm) =240 lbs/min mass flow. Looking at the units
>         we have(8 lbs/gallon)*(30 Gallon/minute) canceling out the
>         like units (gallons) leaves us with 240 lb/minute which is our
>         mass flow in this case.
>
>         Then using the definition of the BTU we have 240 lbs of water
>         that must be raised 10F.  Using our heat transfer equation
>
>         Q = W*deltaT*cp, we have Q = 240*10*1 = 2400 BTU/minute is
>         required to increase the temperature of this mass flow by 10F
>
>         Using the more accurate weight of water we would have  8.34*30
>         =  250.2 lbm/minute  so the actual BTU required is closer to
>         2502 BTU/min instead of my original 2400 BTU/Min, so there is
>         apporx a 4% error in using 8 lbs/gallon.  If we could ever get
>         accurate enough where this 4% was an appreciable part of the
>         total errors in doing our back of the envelope thermodynamics
>         then it would pay to use 8.34 vice 8, but I don't think we are
>         there, yet {:>).
>
>         Now the same basic equation applies to the amount of heat that
>         the air transfers away from out radiators.  But here the mass
>         of air is much lower than the mass of water so therefore it
>         takes a much higher flow rate to equal the same mass flow.
>         What makes it even worse is that the specific heat of air is
>         only 0.25 compared to water's 1.0.  So a lb of air will only
>         carry approx 25% the heat of a lb of water, so again for this
>         reason you need more air flow.  
>
>         if 30 gpm of water will transfer 2400 bTu of engine heat
>         (using Tracy's fuel burn of 7 gallon/hour), how much air does
>         it require to remove that heat from the radiators?
>
>         Well  again we turn to our equation and with a little algebra
>         we have W = Q/(DeltaT*Cp) = 2400/(10*1) = 240 lbm/min. Not a
>         surprise as that is what we started with.
>
>         But now taking the 240 lbm/min mass flow and translating that
>         into Cubic feet/minute of air flow.  We know that a cubic foot
>         of air at sea level weighs approx 0.076 lbs.  So 240
>         lbm/(0.076 lbm/Cubic foot) = 3157 cubic feet/min to equal  the
>         same mass as the coolant. But since the specific heat of air
>         is lower (0.25) that water, we actually need 75% more air mass
>         or 1.75 * 3157 = 5524.75 CFM air flow at sea level. Now I know
>         this sounds like a tremendous amount of air but stay with me
>         through the next step.
>
>         Taking two GM evaporator cores with a total frontal area of
>         2*95 = 190 sq inches and turning that in to square feet = 1.32
>         sq ft we take our 5524.75 cubic feet minute and divide by 1.32
>         sq ft = 4185 ft/min for the required air velocity to move that
>         much air volume through our two evaporator cores.  To get the
>         air velocity in ft/sec divide 4185/60 = 69.75 ft/sec airflow
>         velocity through our radiators  or 47.56 Mph.  Now that sounds
>         more reasonable doesn't it??  
>
>         Now all of this is simply a first order estimate.  There are
>         lots of factors such as the density of the air which unlike
>         water changes with altitude, the temperature of the air, etc.
>         that can change the numbers a bit.  But, then there is really
>         not much point in trying to be more accurate given the
>         limitations of our experimentation accuracy {:>).
>
>
>         Also do not confuse the BTUs required to raise the temperature
>         of 1 lb of water 1 degree F with that required to turn water
>         in to vapor - that requires orders of magnitude more BTU.  
>
>         Hope this helped clarify the matter.
>
>         Ed
>
>
>         Ed Anderson
>         RV-6A N494BW Rotary Powered
>         Matthews, NC
>           ----- Original Message -----
>           From: Mark Steitle
>           To: Rotary motors in aircraft
>           Sent: Friday, August 13, 2004 8:32 AM
>           Subject: [FlyRotary] Re: DeltaT Coolant was : [FlyRotary]
>           Re: coolant temps
>
>
>           Ed,
>           Please humor me (a non-engineer) while I ask a dumb
>           question.  If it takes 1BTU to raise 1lb of water 1 degree,
>           and you factor in 30 gpm flow to come up with a 2400 BTU
>           requirement for a 10 degree rise for 1 lb of water, where
>           does the number of pounds of water figure into the equation,
>           or do we just ignore that issue?  Water is 8.34 lbs/gal, and
>           say you have 2 gallons of coolant, that would be 16.68 lbs.
>           Seems that we would need to multiply the 2400 figure by
>           16.68 to arrive at a total system requirement of 40,032
>           BTU/min.  What am I missing here?
>
>           Mark S.
>
>
>                At 09:58 PM 8/12/2004 -0400, you wrote:
>
>             Right you are, Dave
>              
>             Below  is one semi-official definition of BTU in English
>             units.  1 BTU is amount of heat to raise 1 lb of water 1
>             degree Fahrenheit.  
>              
>             So with Tracy's 30 gpm flow of water = 240 lbs/min.  Since
>             its temperature is raised 10 degree F we have
>              
>             BTU = 240 * 10 * 1 = 2400 BTU/min
>              
>             I know I'm ancient and  I should move into the new metric
>             world, but at least I didn't do it in Stones and Furlongs
>             {:>)
>              
>             Ed
>              
>             The Columbia Encyclopedia, Sixth Edition.  2001.
>              
>             British thermal unit
>              
>              
>             abbr. Btu, unit for measuring heat quantity in the
>             customary system of English units of measurement, equal to
>             the amount of heat required to raise the temperature of
>             one pound of water at its maximum density [which occurs at
>             a temperature of 39.1 degrees Fahrenheit (°F) ] by 1°F.
>             The Btu may also be defined for the temperature difference
>             between 59°F and 60°F. One Btu is approximately equivalent
>             to the following: 251.9 calories; 778.26 foot-pounds; 1055
>             joules; 107.5 kilogram-meters; 0.0002928 kilowatt-hours. A
>             pound (0.454 kilogram) of good coal when burned should
>             yield 14,000 to 15,000 Btu; a pound of gasoline or other .
>              
>              
>              
>              
>              
>              
>              
>             Ed Anderson
>             RV-6A N494BW Rotary Powered
>             Matthews, NC
>               ----- Original Message -----
>               From: DaveLeonard
>               To: Rotary motors in aircraft
>               Sent: Thursday, August 12, 2004 8:12 PM
>               Subject: [FlyRotary] Re: DeltaT Coolant was :
>               [FlyRotary] Re: coolant temps
>
>
>               Ed, are those units right.  I know that the specific
>               heat of water is 1.0 cal/(deg Celsius*gram).  Does that
>               also work out to 1.0 BTU/(deg. Farhengight * Lb.) ? Dave
>               Leonard Tracy my calculations shows your coolant temp
>               drop is where it should be: My calculations show that at
>               7 gph fuel burn you need to get rid of 2369 BTU/Min
>               through your coolant/radiators.  I rounded it off to
>               2400 BTU/min. Q = W*DeltaT*Cp  Basic Heat/Mass Flow
>               equation  With water as the mass with a weight of 8 lbs/
>               gallon and a specific heat of 1.0 Q = BTU/min of heat
>               removed by coolant mass flow
>                Assuming 30 GPM coolant flow = 30*8 = 240 lb/min mass
>                flow. specific heat of water  Cp = 1.0 Solving for
>                DeltaT = Q/(W*Cp) = 2400/(240*1)  =  2400/240 = 10 or
>                your delta T for the parameters specified should be
>                around 10F
>               Assuming a 50/50 coolant mix with a Cp  of 0.7 you would
>               have approx 2400/(240 *0.7) = 2400/168 = 14.2F so I
>               would say you do not fly with
>                a 50/50 coolant mix but something closer to pure water.
>                 But in any case, certainly in the ball park.
>               You reported 10-12F under those conditions, so I would
>               say condition is 4. Normal operation Ed
>               Ed Anderson
>               RV-6A N494BW Rotary Powered
>               Matthews, NC
>
>


--
http://www.bob-white.com
N93BD - Rotary Powered BD-4 (soon)
Subscribe (FEED) Subscribe (DIGEST) Subscribe (INDEX) Unsubscribe Mail to Listmaster