OK, now I see!
At 05:45 AM 8/13/2004 -0700, you wrote:
Mark,
Ed took care of that right in the second line
"So with Tracy's 30 gpm flow of
water = 240 lbs/min"
Dave Leonard
- Ed,
- Please humor me (a non-engineer) while I ask a dumb question.
If it takes 1BTU to raise 1lb of water 1 degree, and you factor in 30 gpm
flow to come up with a 2400 BTU requirement for a 10 degree rise for 1 lb
of water, where does the number of pounds of water figure into the
equation, or do we just ignore that issue? Water is 8.34 lbs/gal,
and say you have 2 gallons of coolant, that would be 16.68 lbs.
Seems that we would need to multiply the 2400 figure by 16.68 to arrive
at a total system requirement of 40,032 BTU/min. What am I missing
here?
- Mark S.
- At 09:58 PM 8/12/2004 -0400, you
wrote:
- Right you are, Dave
-
- Below is one semi-official definition of BTU in English
units. 1 BTU is amount of heat to raise 1 lb of water 1 degree
Fahrenheit.
-
- So with Tracy's 30 gpm flow of water = 240 lbs/min. Since its
temperature is raised 10 degree F we have
-
- BTU = 240 * 10 * 1 = 2400 BTU/min
-
- I know I'm ancient and I should move into the new metric world,
but at least I didn't do it in Stones and Furlongs
{:>)
|
|